Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathCP-PCD-056-00.txt
More file actions
124 lines (105 loc) · 7.55 KB
/
CP-PCD-056-00.txt
File metadata and controls
124 lines (105 loc) · 7.55 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
IHE Change Proposal
Tracking information:
|IHE Domain |Patient Care Device (PCD) |
|Change Proposal ID: |CP-PCD-056 |
|Change Proposal Status: |Ballot |
|Date of last update: |12April2011 |
|Person assigned: |John Rhoads |
Change Proposal Summary information:
|Including BSA as an OBX-3 Observation Identifier |
|Submitter’s Name(s) and e-mail |Brad Lunde, |
|address(es): |bradley.lunde@carefusion.com |
|Submission Date: |11April2011 |
|Integration Profile(s) affected: |PCD |
|Actor(s) affected: |IOP and IOC |
|IHE Technical Framework or |Revision 1.2; September 30, 2010 |
|Supplement modified: | |
|Volume(s) and Section(s) affected: |Volume 2; Section 3.3.4.x.x lines |
| |585-590, lines 880-887 and lines |
| |900-905 |
|Rationale for Change: |
|There are 5 accepted algorithms of calculation BSA based on the height and|
|weight; hospitals can choose to use a combination of all 5 algorithms |
|based on the area of care. This situaiton could lead to the the IOP and |
|the IOC each calculating the BSA differently which in turn would cause the|
|infusion pump to administer a dose incorrectly to the patient. |
|MDC_AREA_BODY_SURF_ACTUAL is an ISO 11073 defined term |
In section 3.3.4.2 update table between lines 585 and 590 with the
following:
|Segment |Meaning |Usage |Card |HL7 Chapter |
|MSH |Message Header |R |[1..1] |2 |
|[{ SFT }] |Software |X | |2 |
|[{ NTE }] |Notes and Comments (for Header) |X | |2 |
|[ |--- PATIENT begin | | | |
| PID |Patient Identification |R |[1..1] |3 |
| [{ NTE }] |Notes and Comments (for PID) |X | |2 |
| [{ AL1 }] |Allergy Information |X | |2 |
| [ |--- PATIENT_VISIT begin | | | |
| PV1 |Patient Visit |O | |3 |
| [ PV2 ] |Patient Visit – Additional Info |X | |3 |
| ] |--- PATIENT_VISIT end | | | |
|] |--- PATIENT end | | | |
|{ |--- ORDER begin | | | |
| ORC |Common Order |R |[1..1] |4 |
| [{ |--- TIMING begin | | | |
| TQ1 |Timing/Quantity |X | |4 |
| [{ TQ2 }] |Timing/Quantity Order Sequence |X | |4 |
| }] |--- TIMING end | | | |
| [ |--- ORDER_DETAIL begin | | | |
| RXO |Pharmacy /Treatment Order |X | |4 |
| [ |--- ORDER_DETAIL_SUPPLEMENT begin| | | |
| { NTE }|Notes and Comments (for RXO) |X | |2 |
| { RXR }|Pharmacy/Treatment Route |X | |4 |
| [{ |--- COMPONENTS begin | | | |
| RXC|Pharmacy/Treatment Component |X | |4 |
| [{ NTE|Notes and Comments (for each RXC)|X | |2 |
|}] | | | | |
| }] |--- COMPONENTS end | | | |
| ] |--- ORDER_DETAIL_SUPPLEMENT end | | | |
| ] |--- ORDER_DETAIL end | | | |
| [ |--- ENCODING begin | | | |
| RXE |Pharmacy/Treatment Encoded Order |X | |4 |
| { |--- TIMING_ENCODED begin | | | |
| TQ1 |Timing/Quantity |X | |4 |
| [{ TQ2 }]|Timing/Quantity Order Sequence |X | |4 |
| } |--- TIMING_ENCODED end | | | |
| { RXR } |Pharmacy/Treatment Route |X | |4 |
| [{ RXC }] |Pharmacy/Treatment Component |X | |4 |
| ] |--- ENCODING end | | | |
| { |--- GIVE begin | | | |
| RXG |Pharmacy/Treatment Give |R |[1..1] |4 |
| { |--- TIMING_GIVE begin | | | |
| TQ1 |Timing/Quantity |X | |4 |
| [{ TQ2 }]|Timing/Quantity Order Sequence |X | |4 |
| } |--- TIMING_GIVE end | | | |
| { RXR } |Pharmacy/Treatment Route |R |[1..1] |4 |
| [{ RXC }] |Pharmacy/Treatment Component |X | |4 |
| { |--- OBSERVATION begin | | | |
| [ OBX ]|Observation/Results |R |[1..34]|7 |
| [{ NTE }]|Notes and Comments (for OBX) |X | |2 |
| } |--- OBSERVATION end | | | |
| } |--- GIVE end | | | |
|} |--- ORDER end | | | |
In section 3.3.4.4.8 lines 880-887 update the following lines:
Point-of-Care Infusion Verification Profile the usage is limited to (1)
providing the Device ID
that will be used by the Infusion Order Consumer and (2) providing patient
height, and weight or
body surface area (BSA) information from the Infusion Order Programmer to
the Infusion Order Consumer.
Note that the definition of the OBX segment in this profile is constrained
from the definition used in the PCD Observation/Result Message to reflect
this limited usage. The broader definition can be found in
B.8 OBX - Observation/Result segment.
One OBX segment containing the Device ID must always be present. One or two
One to three additional OBX segments containing the patient height and/or
patient weight and/or patient BSA may optionally follow.
In section 3.3.4.4.8 lines 900-905 add the following line:
OBX-3 Observation Identifier
The PCD PIV profile constrains the value of this field to one of the
following:
68063^MDC_ATTR_PT_WEIGHT^MDC
68060^MDC_ATTR_PT_HEIGHT^MDC
69986^MDC_DEV_PUMP_INFUS_VMD^MDC
69986^MDC_DEV_PUMP_INFUS_VMD^MDC
57672^MDC_AREA_BODY_SURF_ACTUAL^MDC