Notifications
You must be signed in to change notification settings - Fork 0
Expand file tree
/
Copy pathCP-PCD-053-MiscTFUpdates-20110603.txt
More file actions
176 lines (141 loc) · 9.76 KB
/
CP-PCD-053-MiscTFUpdates-20110603.txt
File metadata and controls
176 lines (141 loc) · 9.76 KB
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
IHE Change Proposal
Tracking information:
|IHE Domain |Patient Care Devices |
|Change Proposal ID: |CP-PCD-053-01 |
|Change Proposal Status: |Submitted |
|Date of last update: |05/18/2011 |
|Person assigned: |(assigned by Domain Technical |
| |Committee) |
Change Proposal Summary information:
|PIV Open Issues section |
|Submitter’s Name(s) and e-mail |Jeff Rinda |
|address(es): |(jeff.rinda@hospira.com) |
|Submission Date: |05/18/2011 |
|Integration Profile(s) affected: |Point-of-Care Infusion |
| |Verification (PIV) |
|Actor(s) affected: |None |
|IHE Technical Framework or |Technical Framework version 1.2 |
|Supplement modified: |(9/30/2010) |
|Volume(s) and Section(s) |Vol 1 – PIV section |
|affected: |Vol 2 – Section 3.3.4.1; also |
| |update reference to PIV |
| |application error table |
| |PIV Application Error table |
| |(standalone document) |
|Rationale for Change: |
|Added new application error messages |
|Add a more specific reference in the TF vol 2 (B.3 ERR segment; |
|ERR-5 section) about where the application error table can be found |
|on the IHE site (since this table is not included in the TF text). |
|Added a Limitations section to Vol 1 including an explanation for |
|how the PIV profile can support rate changes or titrations. |
|Added a statement to Vol. 2 about the use of information in the |
|PCD-03 transaction. |
Replace the PIV application error table (Table 0533 Application Error Code)
with the following version (current as of 5/18/2011). Insert a reference
in Vol 2 about the existence and location of this table (since it is not
included as part of the TF).
Table 0533 Application Error code
|Value |Description |Comment |
|9001 |Unknown infuser or channel |e.g. incorrect infuser|
| | |or channel ID |
|9002 |Infuser/channel is currently infusing | |
|9003 |Missing required program parameter(s) |e.g. Give Amount |
| |(ParameterName1, ParameterName2, ...) |Minimum (RXG-5) - |
| | |volume to be infused -|
| | |is missing |
|9004 |Invalid program parameter(s) |e.g. volume units are |
| |(ParameterName1, ParameterName2, ...) |not mL |
|9005 |Parameter (ParameterName) outside of |e.g. ordered rate |
| |allowable range (MinValue to MaxValue) |greater than pump |
| | |maximum |
|9006 |Infuser is powered off | |
|9007 |Infuser is offline or unable to connect |e.g. infuser not on |
| |to infuser |network or weak |
| | |wireless signal |
|9008 |Invalid units for parameter |e.g. Give Strength |
| |(ParameterName) |Volume Units (RXG-24) |
| | |contains a medication |
| | |unit value instead of |
| | |volume units |
|9009 |Dose/Rate Units do not match drug |e.g. ordered units = |
| |library |mL/hr; drug library |
| | |units =mcg/kg/min |
|9010 |Unable to match medication to drug |e.g. Medication does |
| |library |not exist in drug |
| | |library |
|9011 |Patient weight mismatch |e.g. patient weight |
| | |known by pump differs |
| | |from weight sent in |
| | |PCD-03 |
|9012 |Patient ID mismatch |e.g. patient ID known |
| | |by pump differs from |
| | |ID sent in PCD-03 |
|9013 |Unable to program medication as |e.g. medication not |
| |piggyback |configured for |
| | |piggyback |
| | |administration in drug|
| | |library |
|9014 |Dose rate or VTBI exceeds maximum |e.g. greater than pump|
| | |maximum |
|9015 |Request timed out | |
|9016 |Unknown error |Used when other errors|
| | |are not applicable |
|9017 |Infuser cannot accept program |Infuser is in a state |
| | |where it cannot accept|
| | |program; e.g. alarming|
| | |or in standby |
|9018 |Parameter (ParameterName) does not match|e.g. Give Strength |
| |drug library |Units (RXG-18) = mg, |
| | |drug library = mEq |
|9019 |Patient weight missing |Drug is weight-based |
| | |or BSA-based, but |
| | |patient weight OBX is |
| | |missing |
|9020 |Patient height missing |Drug is BSA-based, but|
| | |patient height OBX is |
| | |missing |
|9021 |Care area or profile mismatch |Care area or profile |
| | |not cleared on pump; |
| | |or pump is set to a |
| | |different care area |
|9022 |Requested infusion program is stale |The value of ORC.9 is |
| | |older than what the |
| | |IOC will allow to |
| | |program the pump |
The following is a revision of text that was formerly contained in the Open
Issues section of the PIV supplement. This text should be incorporated
into TF Vol 1 as a PIV “Limitations” section.
Limitations
1. The principal use case involves starting a new infusion or container.
Titrations or rate changes on a previously programmed infusion are
supported if one of the following applies:
a) The Infusion Order Programmer is able to provide the amount of the
volume currently present in the bag in the PCD-03 transaction (rather
than the ordered volume)
b) The BCMA application provides an acceptable workflow for the clinician
to adjust the volume to be infused directly on the pump from the
amount ordered to the amount currently present in the bag
c) The Infusion Order Consumer is able to interpret the PCD-03
transaction as a rate change without explicit identification as such
(since there is no element in the transaction that refers to whether
it is for a new bag vs. a rate change).
2. Patient-controlled analgesia (PCA) infusion devices are not supported.
3. The following therapies, modes, and methods of operation are not
supported:
a) Bolus, loading dose, multi-step, periodically repeating or ramp/taper
therapies
b) Delayed start mode
c) Programming concurrent or sequenced infusions on more than one pump
channel using a single transaction
4. PIV can be used to support administration of medications from a syringe
and/or using a syringe pump device if the Infusion Order Consumer does not
require the syringe size to be specified.
Add the following change toTF Vol 2 in Section 3.3.4.1
PCD-03 Communicate Infusion Order (RGV^O15^RGV_O15) static definition
The PCD-03 Communicate Infusion Order message is used to communicate
infusion data from an Infusion Order Programmer (IOP) to an Infusion Order
Consumer (IOC).
Since the IOC is typically a gateway rather than an infusion pump, all of
the information specified in the PCD-03 Communicate Infusion Order
transaction is not necessarily provided to or used to program the device.